Skip to main content
Xentra Medical

Laboratory medicine · staged configuration

Build the laboratory your clinical services actually need.

Compare essential, comprehensive and advanced laboratory capability around test scope, workload, people, infrastructure and long-term operation. Confirmed project needs determine the final configuration.

Compare configuration levels
Project fitNew laboratory, capability upgrade or focused module
Primary outcomeA workable service, equipment and operating framework

Sample to result

From sample collection to the final report.

Equipment decisions follow the sample journey, quality controls and reporting responsibilities.

  1. 01

    Collection

    Identify the patient and collect the correct specimen.

  2. 02

    Reception

    Register, accept and prioritize urgent samples.

  3. 03

    Pre-analysis

    Prepare, separate, store and route samples safely.

  4. 04

    Testing

    Run methods, controls and repeat rules.

  5. 05

    Review

    Validate flags and escalate abnormal findings.

  6. 06

    Report

    Release, communicate and retain results.

See what changes when the clinical role and workload grow.

No.Representative systemPrimary purpose
01
Performs complete blood counts with a three-part white-cell differential to support screening for anemia, infection and platelet abnormalities.
02
Uses manual sample loading for glucose, liver and renal profiles, lipids, uric acid, proteins, routine enzymes and other clinical chemistry assays.
03
Automates routine clinical chemistry to reduce manual pipetting and improve efficiency in low- to medium-volume laboratories.
04
Measures sodium, potassium, chloride, ionized calcium and other major electrolytes to support fluid-balance and acid-base assessment.
05
Performs routine PT, aPTT, TT and fibrinogen testing to support preoperative screening and coagulation assessment.
06
Performs urine dipstick testing for protein, glucose, ketones, occult blood, leukocytes, nitrite, pH and other parameters.
07
Supports manual review of blood films, malaria parasites, urine sediment, stool parasites, Gram stains and abnormal automated results.
No.Representative systemPrimary purpose
01
Performs complete blood counts with a five-part white-cell differential to support assessment of anemia, infection, inflammation and platelet abnormalities.
02
Performs routine liver, renal, glucose, lipid, protein and enzyme assays together with sodium, potassium, chloride and other electrolyte testing.
03
Automates routine coagulation assays and supported tests such as D-dimer to help assess bleeding, thrombosis and anticoagulant therapy.
04
Rapidly measures pH, pCO₂, pO₂ and major electrolytes; selected configurations also measure glucose, lactate and other parameters.
05
Performs immunoassays for thyroid and reproductive hormones, cardiac and inflammatory markers, tumor markers, infectious-disease serology and other supported tests.
06
Automates urine chemistry and formed-element sediment analysis to improve efficiency and standardization.
07
Supports manual review of blood films, malaria parasites, urine sediment, stool parasites, Gram stains and abnormal automated results.

PROFESSIONAL MODULES

Professional extension modules are selected according to the hospital's disease profile, sample volume, clinical needs, staffing and biosafety conditions.

HbA1c analysis

Supports diabetes diagnosis and long-term assessment of glycemic control.

ELISA testing

Uses a microplate reader and washer where local testing policy still requires batch immunoassay or infectious-disease testing by ELISA.

Clinical microbiology

Adds automated blood culture and microbial identification and antimicrobial-susceptibility analysis according to sample volume.

No.Representative systemPrimary purpose
01
Processes complete blood counts and five-part differentials in volume, with automated loading, abnormal-result flags, reruns and STAT sample handling.
02
Automates blood-film preparation, staining and digital scanning, with preclassification of abnormal cells for expert morphology review.
03
Continuously processes high volumes of routine and extended chemistry assays, with automated loading, dilution, reruns, STAT handling and electrolyte testing.
04
Continuously processes high volumes of coagulation and hemostasis assays with automated loading, reruns and STAT sample handling.
05
Continuously processes high immunoassay volumes with continuous sample and reagent loading, STAT handling and automated reruns.
06
Rapidly measures pH, pCO₂, pO₂ and major electrolytes; selected configurations also measure glucose, lactate and other parameters.
07
Measures HbA1c by high-performance liquid chromatography to support diabetes care and long-term glycemic assessment, with the ability to flag selected hemoglobin variants.
08
Supports screening and characterization of sickle cell disease, thalassemia and other hemoglobin disorders.
09
Measures immunoglobulins, complement, inflammation-related proteins and other specific proteins supported by the platform.
10
Integrates urine chemistry, sediment analysis, automated loading, image review and reruns of abnormal samples.
11
Continuously incubates and monitors blood-culture bottles, automatically flagging positive results to support early diagnosis of bloodstream infection and sepsis.
12
Identifies cultured isolates and tests antimicrobial susceptibility to inform infection treatment and antimicrobial-resistance surveillance.
13
Rapidly identifies pure cultured colonies, shortening identification time for common bacteria and fungi.
14
Processes sample lysis, nucleic-acid binding, washing and elution in batches, improving consistency, efficiency and traceability before molecular testing.
15
Runs approved and validated qualitative or quantitative pathogen assays, including applicable tests for HIV, viral hepatitis, tuberculosis and respiratory pathogens.
16
Automates sample preparation, nucleic-acid extraction, amplification and result analysis within a closed cartridge from sample input to reportable result.

Start a conversation

Choose the collaboration path you want to advance.

Submit a laboratory requirement or introduce your local resources and partnership plan in Africa.

Laboratory configuration

Laboratory configuration requirement

Share the hospital’s current laboratory capability, clinical service scope and development goals to begin a targeted configuration discussion.

Local Partnership

Discuss a locally grounded healthcare project with Xentra Medical.

Share the institution, project context, local stakeholders and the role you would like to discuss.

Discuss a Partnership
Chat with us